Field Strength Meter: See Your Antenna Pattern and RF Leakage

An SWR meter tells you what comes back down the cable. It says nothing about what the antenna does with the power that goes in. The meter on the transceiver tells you how hard the radio is working, and not whether the signal in the air is strong in the direction that you want. A field strength meter fills this gap. It is a small, simple instrument that responds to the radio energy around it, and it can show you whether a change to the antenna made the signal stronger, in which direction the beam really points and where RF is leaking from places where it should not. It is not a precision instrument, but it is cheap, easy to build and surprisingly informative. This article explains how it works, what it can and cannot tell you, how to use it for tuning, patterns and leakage hunting, and how to build one from a handful of parts.
What a Field Strength Meter Is
The quantity that the instrument is named for is the field strength, the strength of the electric field of a radio wave at a point in space, usually expressed in volts per metre or in microvolts per metre. A full calibrated field strength meter has a known antenna, a calibrated receiver and a scale in absolute units, and it is a laboratory device. The amateur version is simpler and relative. It has a short antenna, a detector and a meter, and its reading is a number that rises when the field grows and falls when the field falls. You cannot read volts per metre from it, but you can compare one situation with another, which is exactly what you need for adjusting an antenna.
How a Simple One Works
The circuit has four parts. The pickup is a short whip or a loop of wire that receives a little of the RF. A tuned circuit, a coil and a variable capacitor, can be added to select the frequency and to raise the signal. A Schottky diode or a germanium diode rectifies the RF into a small direct current, as a crystal detector does in a crystal radio. A capacitor smooths the pulses. And a sensitive meter, with a full-scale deflection of 50 to 200 microamperes, shows the result. At very small signals, the diode responds in proportion to the square of the voltage, so the meter rises slowly, and at larger signals it responds almost linearly. For relative comparisons, this is not a problem, as long as you take your readings in a similar range.
| Part | Role | Typical choice |
|---|---|---|
| Pickup | Receives the RF | Telescopic whip of 30 to 100 cm |
| Tuned circuit | Selects the band and raises the signal | Coil with a variable capacitor, or none for a broadband version |
| Detector | Rectifies the RF | Schottky or germanium diode |
| Filter | Smooths the output | Capacitor of 1 to 10 nF |
| Meter | Shows the level | 50 to 200 microampere movement, or a multimeter |
| Sensitivity control | Keeps the needle in range | Potentiometer across the meter |
Tuning an Antenna for Maximum Radiation
The most common use is to adjust an antenna and see the result in the air. Place the meter at a fixed spot at some distance from the antenna, in the direction of its main lobe, and mark the place. Transmit a steady carrier at low power into the antenna, into the band where you work, and note the reading. Now make a change: lengthen a wire, adjust a matching device, move a radial, tilt a reflector. Transmit again and read the meter. If the reading rose, the change helped. It is a direct test of what your antenna does in the air, unlike the SWR, which only reflects the match. A match with a low SWR can be achieved by a lossy system that radiates poorly, and the meter reveals it. The comparison works best when you keep everything else constant: the power, the position of the meter, its antenna and the surroundings.
Use the lowest power that gives a useful reading, and keep the transmissions short, since the meter and its owner may be in the near field of the antenna. Stay at a distance in the far field. As a guide, two times the square of the largest size of the antenna divided by the wavelength is the minimum, and for HF antennas tens of metres is typical. Closer to the antenna, the reading depends on the position more than on the radiation. For a practical test, keep the meter at least several wavelengths away, if the ground allows, or use a long cable to a probe held away from your body.
Plotting a Beam Pattern
A field strength meter turns a beam into a picture. Fix the meter at a distance in the far field, and rotate the antenna in steps of ten or fifteen degrees, noting the reading at each step with a constant power. Plot the readings on polar graph paper, converting them to decibels if you know the response of the detector. The result is the horizontal pattern of the antenna: the main lobe, the width of the beam, the side lobes and the null behind. A comparison with the theory, such as the shape described in the article on the radiation pattern, shows whether the antenna works as designed. A front-to-back ratio that is much worse than expected may point to a problem in the reflector, the phasing or the common-mode current on the feedline. Remember to repeat the measurement over a different spot as a check, since reflections from buildings and trees can distort the reading.
Finding RF Leakage and Common-Mode Current
A second use is a sniffer, a field strength meter with a small probe that you move around the station while you transmit at low power. A rise in the reading near a cable, a case, a power lead or a microphone shows RF where you do not want it. It is a quick way to find the cable that carries common-mode current, to see whether a choke on the coax made a difference and to spot a poorly shielded device. The method fits the problems described in the article on common mode chokes: you place the probe beside the cable, note the reading, add the choke and compare. The same instrument can show weak spots in the shielding of an amplifier and signs of leakage from a connector that has worked loose.
The meter is not a test for RF exposure limits. Safety assessments need calibrated instruments and a different method, as the article on RF exposure safety explains. Use the sniffer to find and cure leaks and not to decide that a place is safe.
Checking Harmonics and Spurious Signals
A tuned field strength meter can give a rough hint of harmonics. Tune the meter to the fundamental, note the reading and then tune it to the second harmonic, for example 14 MHz and 28 MHz. A tuned version responds strongly to its own frequency and weakly to the others, so a reading at the harmonic that is a good fraction of the fundamental suggests a problem, perhaps a missing low-pass filter. Without calibration, you cannot give the harmonic level in decibels, so for a real measurement use a spectrum analyzer or a receiver with an S-meter calibrated in decibels, as in the guide to SDR receivers, and keep the field strength meter as a quick check. The cure is shown in the article on the low-pass filter.
Limits of the Simple Meter
It helps to be honest about what the instrument cannot do. A broadband meter responds to any strong signal, so a nearby broadcast station, a mobile phone or a switching power supply can disturb the reading, and the tuned version reduces but does not remove this problem. The diode is temperature sensitive, so the zero and the sensitivity drift a little between a cold morning and a warm afternoon. The pickup antenna is short compared with the wavelength, so the response changes with frequency, and a reading on 7 MHz cannot be compared with one on 14 MHz without calibration. The result is a relative tool, best for changes made on one band on one day. For absolute work, borrow a calibrated instrument from a club or a friend, and use the home-built one for the many everyday comparisons for which it is perfectly good.
Building One in an Evening
A basic version can be built on a scrap of board in half an hour. Connect a Schottky diode in series from the pickup whip to one side of a microammeter, with a capacitor of a few nanofarads across the meter, and connect the other side of the meter to a ground wire or to the case. This broadband version responds to any strong RF, and its sensitivity depends on the whip and the distance. To add selectivity, place a coil and a variable capacitor in parallel at the input, tuned to the band, and tap the diode across a few turns of the coil. For a more sensitive version, add a transistor or an operational amplifier after the detector to amplify the DC signal, and a potentiometer to set the zero. Put the whole in a small metal box with a telescopic whip. Calibrate it, if you wish, by comparing it with the S-meter of a receiver at a few levels, though the main use remains relative.
Comparing Two Antennas
A field strength meter is also a fair judge when two antennas compete. Put the meter at a fixed place, connect the first antenna, transmit a steady carrier at low power and note the reading. Switch to the second antenna with the same power and compare. Because the detector is not linear, do not infer a ratio in decibels from the needle positions unless you have checked the response: a simple way is to insert a known attenuator, for example 6 dB, between the transmitter and the antenna and see how far the needle moves. That calibration turns the readings into rough decibel differences for that meter and that range. The test favours the antenna that sends more signal towards the meter, so choose a position that represents the direction of the contacts you want, and repeat the comparison in two or three directions. Two antennas that look the same in the SWR may differ clearly in the air, and this is how you find it out.
Tips for Reliable Readings
- Keep the pickup in the same orientation and at the same height for every reading, since polarisation matters.
- Stay away from metal objects, cables and your own body, which change the field near the pickup.
- Use the same power and a steady carrier, such as the tune function, and check that the power did not drift.
- Make several readings and average them, because small movements change the numbers.
- Record the readings in a notebook with the date, the band and the change you made, so that you can go back.
- Do not test in the near field and expect pattern results, since the reading will be wrong.
The Bottom Line
A field strength meter is a pickup, a diode detector and a microammeter that show the relative strength of RF around the station. It lets you test whether a change to an antenna increased the radiated signal, plot the pattern of a beam by rotating it in steps, hunt for common-mode current and leakage with a probe and get a rough hint of harmonics with a tuned version. Measure in the far field, keep conditions constant and treat the reading as relative, not absolute. It is not a safety instrument, but it is the cheapest way to see what your antenna does in the air, and an evening’s work builds a useful one.
Frequently Asked Questions
What does a field strength meter measure?
The relative strength of the RF field at the place where it stands. Simple amateur versions give no absolute units but show whether the field rises or falls.
Can it tune an antenna better than an SWR meter?
It shows what the antenna radiates, which the SWR does not. A low SWR can hide a lossy antenna. Use both: SWR for the match and the field meter for radiation.
How far away should I place it?
In the far field, at least two times the square of the antenna size divided by the wavelength, and in practice several wavelengths or tens of metres on HF.
Can I use it to check RF exposure safety?
No. Exposure assessment needs calibrated instruments. Use the simple meter to find leaks and compare changes, not to declare a place safe.
What meter movement should I use?
A microammeter of 50 to 200 microamperes full scale, with a potentiometer to adjust the sensitivity. A multimeter on a low DC range works too.
Why does the reading change when I move my hand?
Your body and nearby metal alter the field at the pickup. Hold the meter at the same distance from you for each reading, or mount it on a stand.